Pulmonary Oedema ● Extravascular Lung Water Index ELWI 3.0 - 7.0 ml/kg ● ● ● ● ● Pulmonary Vascular Permeability Index PVPI 1.0 - 3.0 -/- ● ● ● ● ● available PULSION Medical Systems is a medical device manufacturer and does not practice medicine. Sie haben weniger dringliche Anliegen? Flow. Q = SV x HR. Preload. Cardiac Preload ● ● ● ● ● Global Enddiastolic Volume Index GEDI 680 - 800 ml/m2 ● ● ● ● Intrathoracic Blood Volume Index ITBI 850 - 1000 ml/m2 IV. Cardiovascular system. Cardiac Index CI 3.0 - 5.0 l/min/m2 III. Kontaktieren Sie unsere Notfallhotline: 0800 1 260 230 . kg −1 (range 7–31), reference range 3–7. Sie benötigen DRINGENDEN technischen oder klinischen Support zu unseren Produkten? Current reference values published for GEDVI and EVLWI are not applicable in children; the former is too high and the latter too low, and should not guide clinical practice. PiCCO Notfallhotline . These are the equations used to arrive at the numbers which the machine spews out after you have done a thermodilution, as well as the normal ranges for those numbers. Unser Kundenservice ist für Sie da. The treating physician is responsible for determining and utilizing the appropriate diagnostic and therapeutic measures for each individual patient. References. Global Enddiastolic Volume Index GEDI 680 - 800 ml/m2 . Cat Cat V+ V+! Normal Range; Partial Pressure of Arterial Oxygen (PaO 2) 80 – 100 mmHg: Partial Pressure of Arterial CO 2 (PaCO 2) 35 – 45 mmHg: Bicarbonate (HCO 3) 22 – 28 mEg/1: pH: 7.38 – 7.42: Arterial Oxygen Saturation (SaO 2) 95 – 100%: Mixed Venous Saturation (SvO 2) 60 – 80%: Arterial Oxygen Content (CaO 2) (0.0138 x Hgb x SaO 2) + (0.0031 x PaO 2) 17 – 20 ml/dl See instructions for use for full … Cardiac Contractility ● ● ● ● ● Cardiac Function Index CFI 4.5 - 6.5 1/min ● ● ● ● ● Global Ejection Fraction GEF 25 - 35 % ● ● ● ● Index of Left Ventricular Contractility dPmx -/- mmHg/s ● ● ● ● ● Cardiac Power Index CPI 0,5 - 0,7 W/m2 VII. PiCCO-Technology: Normal Values - PULSION Medical Systems SE. This chapter is relevant to Section G7(iv) of the 2017 CICM Primary Syllabus, which asks the exam candidate to "describe the methods of measurement of cardiac output including calibration, PiCCO-Technology: Normal Values - PULSION Medical Systems SE, PiCCO-Technology: Normal Values Parameters I. Oxygenation Range Unit PiCCO 2 PiCCO plus CMS Intelli- Vue Dräger Central Venous Oxygenation ScvO2 70 - 80 % ● Oxygen Delivery Index DO2I 400 - 650 ml/min/m2 Oxygen Consumption Index VO2I 125 - 175 ml/min/m ● 2 II. / SpO. CAUTION: Federal (United States) law restricts this device to sale by or on the order of a physician. Normal Range; Arterial Blood Pressure (BP) Systolic (SBP) 90 - 140 mmHg : Diastolic (DBP) 60 - 90 mmHg: Mean Arterial Pressure (MAP) (SBP + 2 x DBP)/3: 70 - 105 mmHg: Systolic Pressure Variation (SPV) (SPmax-SPmin) <5 mmHg unlikely to be preload responsive >5mmHg likely to be preload responsive: Pulse Pressure Variation (PPV) (PPmax-PPmin)/[(PPmax + PPmin)/2] x100 For professional use. 2. +49-(0)89-45 99 14-0 • Fax +49-(0)89-45 99 14-18 info@pulsion.com • www.PULSION.com, Magazine: PiCCO-Technology: Normal Values - PULSION Medical Systems SE. 20 • D-81829 Munich, Germany • Tel. Normal Hemodynamic Parameters and Laboratory Values Normal Hemodynamic Parameters – Adult. 8.7-11.2 mmol/l (Male) 7.5-9.9 mmol/l (Female) Arterial / capillary oxygen saturation (Oxygen load of arterial blood) SaO. Flow ● Cardiac Index CI 3.0 - 5.0 l/min/m2 III. 2 II. From Bersten and Soni’s” Oh's Intensive Care Manual”, 6th Edition, as well as http://www.pulsion.com/ who are sadly the best source for this sort of information. This chapter is relevant to Section G7(iv)  of the 2017 CICM Primary Syllabus, which asks the exam candidate to. Previous chapter: EVLW: extravascular lung water volume; Next chapter: PiCCO-guided resuscitation of shock; ... Next chapter: PiCCO-guided resuscitation of shock .